Analysis of air conditioning in the foundry.

We conducted an air conditioning analysis of the factory interior space with ventilation from outside during calm conditions.

The air conditioning analysis within the casting factory was conducted to assess the air conditioning of the factory space with external ventilation during calm conditions. In facilities such as factories, functionality such as air conditioning performance and ventilation efficiency takes precedence over design. When considering the ventilation and air conditioning performance of the factory space, even if the ventilation and air conditioning airflow is set according to the heat generation of each section, the movement of air between sections does not guarantee that the living area is always maintained at the specified temperature. Therefore, careful consideration of the nozzle arrangement and airflow settings is necessary. For more details, please download the catalog.

  • Scientific Calculation and Simulation Software
  • Other Software

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Analysis of Air Conditioning in Cold Storage Warehouse

An example of a freezer equipped with an automatic transport system was provided, and an air conditioning analysis was conducted.

The air conditioning analysis in a refrigerated warehouse was conducted using an example of a freezer equipped with an automatic conveyor. Air conditioning analysis has traditionally been performed in large spaces such as atriums and domes, but recently it has increasingly been applied to specialized spaces as well. Examples include automated warehouses, clean rooms, underfloor air conditioning, displacement systems, and food factories, each of which often has stringent air conditioning performance requirements, making it difficult to set equipment specifications. For more details, please download the catalog.

  • Duct related equipment
  • Scientific Calculation and Simulation Software
  • Other Software

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Server room (data center) air conditioning analysis

Analyzing the effects of aisle capping in the server room!

In server rooms and data centers, there are many servers and IT equipment, and heat management is essential for their stable operation. As a measure, we face the exhaust fans on the back of the server racks towards each other to create a pathway (hereinafter referred to as the hot aisle) that primarily directs exhaust from the racks upward, and we face the intake sides on the front of the server racks towards each other to create a pathway (hereinafter referred to as the cold aisle) that primarily introduces cool air from the floor into the server racks, alternating them to enable efficient exhaust. However, at the top of the server racks, there is a possibility of drawing in high-temperature exhaust from the equipment (short-circuiting), so we considered measures and conducted a comparison based on the presence or absence of a partition (hereinafter referred to as aisle capping) at the top of the cold aisle. For more details, please download the catalog.

  • Scientific Calculation and Simulation Software
  • Other Software

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Entrance hall air conditioning analysis

Air conditioning analysis of the entrance hall was conducted during the basic design phase.

The entrance hall targeted for analysis is a large space with a height of approximately 20 meters. During the basic design phase, it is crucial to verify whether there are any issues with the temperature distribution and airflow distribution in the living area, based on the position, number, wind speed, and temperature of the air conditioning air outlets. This is very important for considering comfort and energy efficiency. Additionally, changes in conditions due to the seasons must also be taken into account. In this analysis, we detailed the internal space shape of the building, the arrangement of air outlets and inlets, and the thermal load, conducting air conditioning analysis for summer, winter, and transitional periods. For more details, please download the catalog.

  • Scientific Calculation and Simulation Software
  • Other Software

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Air Conditioning Analysis in an Electrical Components Factory

We conducted an air conditioning analysis using an electrical components factory with a clean room as an example.

The air conditioning analysis of an electrical components factory was conducted using a factory with a clean room as an example. Unlike general architecture, where aesthetics are emphasized, in facilities such as factories, functionality such as air conditioning performance and ventilation efficiency takes precedence over design. Even when achieving the same ventilation and air conditioning performance, there is often significant potential for cost reduction regarding the layout of ducts and outlets. For more details, please download the catalog.

  • Duct related equipment
  • Scientific Calculation and Simulation Software
  • Other Software

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration